Technical Specifications
Mechanical
DimensionsUA-Lock-Magnetic-270kg
Lock body: 250 x 42.5 x 26 mm(9.8 x 1.7 x 1" )
Install plate: 250 x 25x 5 mm (9.8 x 1 x 0.2" )
Armature: 185.5 x 38.5 x 11 mm (7.3 x 1.5 x 0.4")

UA-Lock-Magnetic-540kg
Lock body: 266 x 67.5 x 40 mm (10.5 x 2.7 x 1.6")
Install plate: 266 x 40 x 6 mm (10.5 x 1.6 x 0.2")
Armature: 185 x 61 x 16 mm (7.3 x 2.4 x 0.6")
WeightUA-Lock-Magnetic-270kg
Lock body: 1 kg (2.2 lb)
Install plate: 70 g (0.15 lb)
Armature: 600 g (1.3 lb)

UA-Lock-Magnetic-540kg
Lock body: 2.9 kg (6.4 lb)
Install plate: 145 g (0.3 lb)
Armature: 1.4 kg (3.1 lb)
Enclosure materialDevice/brackets: aluminum
Armature: steel
Hardware
Voltage12V DC
Current powerUA-Lock-Magnetic-270kg: 800mA ±10%
UA-Lock-Magnetic-540kg: 500mA ±10%
Wiring connectionConnect below terminals to UA-Hub:
Lock 12V/NC (connect to Power Lock Relay NC on UA-Hub)
Lock 12V/COM (connect to Powered Lock Relay COM on UA-Hub)
DPS/+ (DPS+ on UA-Hub)
DPS/-(DPS-onUA-Hub)
Lock typeFail safe lock
Single door
Holding forceUA-Lock-Magnetic-270kg: 270 kg (600 lb)
UA-Lock-Magnetic-540kg: 540 kg (1,200 lb)
LEDGreen: unlocked
Red: locked
SuitabilityUA-Lock-Magnetic-270kg: wooden/metal/glass door
UA-Lock-Magnetic-540kg: wood/metal door
Mounting accessoriesUA-Lock-Magnetic-270kg
L bracket : door thickness < 42 mm (< 1.7"), outward opening door
Z bracket: used with L bracket for inward opening door
U bracket: used with glass door

UA-Lock-Magnetic-540kg
L bracket: door thickness < 42 mm (< 1.7"), outward opening door
Z bracket: used with L bracket for inward opening door
Ambient operating temperature-10 to 50° C (14 to 122° F)
Ambient operating humidity5 to 90% noncondensing
CertificationsFCC, IC, CE